Sign In | Join Free | My himfr.com
Home > Expulsion Drop Out Fuse >

High Voltage Expulsion Drop Out Fuse Brass Components GB1208 2006 Standard

    Buy cheap High Voltage Expulsion Drop Out Fuse Brass Components GB1208 2006 Standard from wholesalers
     
    Buy cheap High Voltage Expulsion Drop Out Fuse Brass Components GB1208 2006 Standard from wholesalers
    • Buy cheap High Voltage Expulsion Drop Out Fuse Brass Components GB1208 2006 Standard from wholesalers

    High Voltage Expulsion Drop Out Fuse Brass Components GB1208 2006 Standard

    Ask Lasest Price
    Brand Name : XK
    Model Number : PD-36
    Certification : ISO9001 / GB / IEC
    Supply Ability : 100 Piece/Pieces per Month
    Price : Negotiation
    • Product Details
    • Company Profile

    High Voltage Expulsion Drop Out Fuse Brass Components GB1208 2006 Standard

    Factory direct dropout fuse cutout brass components/brass expulsion cut out components with good price

    Product Description

    TypePD - 36/100PD - 36/200
    Rated Voltage(kV)3636
    Rated current(A)100200
    Breaking current(A)1000012,000
    Impulse voltage(kV)170170
    Power frequency wihstand voltage(kV)7070
    Creepage distance(mm)720720
    Weight(kg)55
    Dimensions(CM)61X34X11.561X34X11.5

    Expulsion Drop-Out Fuse Barrel Inspection and Fuse Rating Requirements
    Purpose
    The purpose of this instruction is to provide all Horizon Power Workers the minimum inspection
    and fuse rating requirements for Drop-Out Expulsion Fuses (DOF).
    Safety
    Before commencement of work, a risk assessment must be carried out using the Risk Analysis
    Procedure (OSH-3.6-1-02), to identify and document the hazards and risks associated with the
    task and ensure appropriate control measures are implemented.
    It is important that, appropriate control measures must be identified, documented and implemented
    in order to control hazards to As Low as Reasonable Practicable (ALARP).
    Instruction
    DOF’s have a limited life span and must be checked for serviceability prior to their installation by
    using a Wear Rod. (See Fig. 1)
    The Wear Rod measures the diameter and length of the DOF barrel insert and the inside diameter
    of the DOF barrel.
    Wear Rod
    The wear rod is used to find out whether the barrel has any abnormalities, for example, the fuse
    element may not clear and the barrel may not drop away, causing extensive damage to the fuse
    barrel.
    A flash over may result, shorting out the adjacent phases and tripping the feeder.
    When using the wear rod, the operator should check the following:
    • Its 500 mm length must pass down the barrel
    • Its 13.5 mm diameter section is used to check the diameter of the inner tube at the
    expulsion end. The rod should not penetrate the inner tube
    • The 5 mm notch from one end is used to check the shrinkage of the inner tube. The
    shrinkage should not exceed this distance
    • The fuse barrel must be replaced if any of these tests cannot be correctly performed