Sign In | Join Free | My himfr.com
Home > Load Break Switch >

11kv Pad Mounted Transformer Load Break Switch 3 Phase High Efficiency

    Buy cheap 11kv Pad Mounted Transformer Load Break Switch 3 Phase High Efficiency from wholesalers
     
    Buy cheap 11kv Pad Mounted Transformer Load Break Switch 3 Phase High Efficiency from wholesalers
    • Buy cheap 11kv Pad Mounted Transformer Load Break Switch 3 Phase High Efficiency from wholesalers

    11kv Pad Mounted Transformer Load Break Switch 3 Phase High Efficiency

    Ask Lasest Price
    Brand Name : XK
    Model Number : FN12
    Certification : ISO9001 / GB / IEC
    Supply Ability : 100 Piece/Pieces per Month
    Price : Negotiation
    • Product Details
    • Company Profile

    11kv Pad Mounted Transformer Load Break Switch 3 Phase High Efficiency

    11kv load break switch 3 phase load break switch indoor load break switch

    Hot sale 11KV safety indoor AC high voltage load breaker switch

    Product Description

    11kv Pad Mounted Transformer Load Break Switch 3 Phase High Efficiency

    ltemUnitData
    Rated voltageKVFN12-12D/630FN12-12(R)D/125
    Rated frequencyHZ12
    Rated currentA50
    1min power frequency withstand voltageKV42 to ground and phases fracture 48
    Lightning impulse withstand voltageKV75 to ground and phases fracture 85
    Rated thermal stable currentKA
    630
    100
    Rated dynamic stable currentKA
    50
    Rated switching current(peak)KA
    50
    50
    Rated short-circuit current(expected)KV
    31.5
    Maximum breaking current thresholdHZFuse characteratic curve accorting
    Minimum breaking currentAFuse characteratic curve accorting
    Rated transfer currentKV
    50
    1.5
    Maximum breaking currentKV1.8
    Breaking OFF-load transformer capacityKV/A1250
    Rated cable charging currentA10
    Rated active load current breaking timesTimes10000
    Opening time when striker strikesS<0.06
    Earth switch thermal current switchKA20(2S)
    Thermal stable current of earth switchKA5050
    Motor operating power supply voltageVAC/DC 110/220

    11kv load break switch 3 phase load break switch indoor load break switch

    ltemUnitData
    FN12-10D/630FN12-10(R)D/125
    The total traveling distance of moving contactmm200+8-2
    Phase center distance (Before energy storage)mm210±15
    Moving contact overtravel distancemm40±2
    Auxiliary contact opening distancemm>150
    Opening/Closing time difference among three phasems<3
    Opening speedm/s>2.8>2.8
    Closing speedm/s>3.8
    Distance between metal flexible door and torchmm>125
    Fracture distance of earth switchmm>150
    Main circuit resistanceΩ<120<300
    Maximum operating torqueNM>160

    11kv load break switch 3 phase load break switch indoor load break switch

    11kv Pad Mounted Transformer Load Break Switch 3 Phase High Efficiency


    Ascending changes in the way we generate, transmit and use of electricity in developed economy or highly industrialised society, prioritised the maintenance of continuity of supply to consumers. With the goal to be integrated in smart cities, the safety of electrical equipment by fast disconnection of the power supply in case of fault events like leakage current, electrical arc, over current or overvoltage is taken care through switchgear such as disconnecting switches, circuit breakers, etc. For the systems up to 33kV, the more costly circuit breakers are getting replaced with load break switches. A load break switch is a type of switching device used for voltages in the range of 12 to 36 kV and must have the following capabilities:

    - Interruption of current equal to its continuous current rating at the system voltage and the power factor of the normal load
    - Designed to possess enough insulation to isolate the circuit in closed position.
    - Interrupting small capacitive and inductive currents which is essential for disconnecting the unloaded overhead lines, transformers, cables, etc.
    - Carrying the maximum fault current for the duration required by the interrupting device to clear the fault.
    - Making on the terminal fault at rated voltage.

    The basic functional difference between Load break switch and circuit breaker is that the former cannot interrupt the short circuit currents. The following figure 1 shows the how the load break switches are employed in a substation.

    Quality 11kv Pad Mounted Transformer Load Break Switch 3 Phase High Efficiency for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: ZHEJIANG XINKOU POWER EQUIPMENT CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)