12kv Load Disconnect Switch / Hv Outdoor High Voltage Isolator ISO9001

    Buy cheap 12kv Load Disconnect Switch / Hv Outdoor High Voltage Isolator ISO9001 from wholesalers
     
    Buy cheap 12kv Load Disconnect Switch / Hv Outdoor High Voltage Isolator ISO9001 from wholesalers
    • Buy cheap 12kv Load Disconnect Switch / Hv Outdoor High Voltage Isolator ISO9001 from wholesalers

    12kv Load Disconnect Switch / Hv Outdoor High Voltage Isolator ISO9001

    Ask Lasest Price
    Brand Name : XK
    Model Number : FN12
    Certification : ISO9001 / GB / IEC
    Supply Ability : 100 Piece/Pieces per Month
    Price : Negotiation
    • Product Details
    • Company Profile

    12kv Load Disconnect Switch / Hv Outdoor High Voltage Isolator ISO9001

    Hot sale 12KV safety indoor AC high voltage load breaker switch

    Product Description

    12kv Load Disconnect Switch / Hv Outdoor High Voltage Isolator ISO9001

    ltemUnitData
    Rated voltageKVFN12-12D/630FN12-12(R)D/125
    Rated frequencyHZ12
    Rated currentA50
    1min power frequency withstand voltageKV42 to ground and phases fracture 48
    Lightning impulse withstand voltageKV75 to ground and phases fracture 85
    Rated thermal stable currentKA
    630
    100
    Rated dynamic stable currentKA
    50
    Rated switching current(peak)KA
    50
    50
    Rated short-circuit current(expected)KV
    31.5
    Maximum breaking current thresholdHZFuse characteratic curve accorting
    Minimum breaking currentAFuse characteratic curve accorting
    Rated transfer currentKV
    50
    1.5
    Maximum breaking currentKV1.8
    Breaking OFF-load transformer capacityKV/A1250
    Rated cable charging currentA10
    Rated active load current breaking timesTimes10000
    Opening time when striker strikesS<0.06
    Earth switch thermal current switchKA20(2S)
    Thermal stable current of earth switchKA5050
    Motor operating power supply voltageVAC/DC 110/220

    12kv load break switch air load break switch outdoor hv break switch

    ltemUnitData
    FN12-10D/630FN12-10(R)D/125
    The total traveling distance of moving contactmm200+8-2
    Phase center distance (Before energy storage)mm210±15
    Moving contact overtravel distancemm40±2
    Auxiliary contact opening distancemm>150
    Opening/Closing time difference among three phasems<3
    Opening speedm/s>2.8>2.8
    Closing speedm/s>3.8
    Distance between metal flexible door and torchmm>125
    Fracture distance of earth switchmm>150
    Main circuit resistanceΩ<120<300
    Maximum operating torqueNM>160

    12kv load break switch air load break switch outdoor hv break switch

    12kv Load Disconnect Switch / Hv Outdoor High Voltage Isolator ISO9001


    Load Break Switch VS Circuit Breaker
    There are two important different parameters as far as the disconnection/connection of Electrical utilities is concerned.
    - Breaking capacity.
    - Making Capacity.

    Making capacity is more higher since it is considering the initial starting current, inrush and faults that might occur at switching on moment.

    Accordingly, the Circuit breakers have both while the Isolator or LBS has only breaking capacity. Isolator therefore used to isolate/disconnect/break load. To be switched on only under no load.

    Basically and LBS is only designed to make and break load currents. It can be closed onto a fault (has a making rating) and cannot break a fault current. A CB is designed to make and break fault currents and off course load currents. Need to be careful with switching long cables and long lines with LBS, due to its limitation with switching cable/line charging (highly capacitive) currents. Similar precaution with needed with switching reactive loads like large transformers. Normally a CB is recommended for the 2 latter cases. Check the manufacturer test specs.

    In simple way the Load Break Switch used to cut off healthy circuits or to break / disconnect the load. As a precaution, normally the LBS / Isolator are to be switched on under no load, the connected load to be utilized after switching on the Isolator. This why it has no making capacity. Circuit Breakers are intended to operate under unnormal conditions in order to clear the fault & to isolate the defective circuits protecting its associated electrical equipment, therefore breaking and making capacities are considered as the most important criteria as far Circuit breaker are concerned.

    The making current is not an RMS value it is the peak value ie. Impk = 2.5Irms. The peak value of 2.5 times RMS is the DC offset at point when the LBS closes on the fault and is taken as the worst case X/R ratio of the source (X/R of about 20). This peak decays to RMS value Ith (thermal withstand current) dependent on the X/R delay constant. The decay rate is exponential with time. There is a misconception that making is 2.5times breaking current, but making is normally quoted as a peak and breaking as RMS. The breaking current in a CB is an RMS value. Breaking fault current is far more difficult that making especially when the contacts open when current is not at zero crossing point on the sine wave. For HV systems 132KV and above, the restrike and TRV starts to become a major consideration in CB selection, especially for long cables and lines.